<item>
	<title>Figure 2-20 24VDC Power Distribution Wiring Schematic</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53915</link>
	<pubDate>Fri, 27 Aug 2004 10:29:14 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53915">]]></description>
	
</item>

<item>
	<title>Figure 2-20 24VDC Power Distribution Wiring Schematic</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53914</link>
	<pubDate>Fri, 27 Aug 2004 10:28:51 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53914">]]></description>
	
</item>

<item>
	<title>Figure 2-19 Typical FVC &amp; VFD Motor Control Electrical Schematic </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53913</link>
	<pubDate>Fri, 27 Aug 2004 10:28:29 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53913">]]></description>
	
</item>

<item>
	<title>Figure 2-18 Pressure Gauge Mounting Detail </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53912</link>
	<pubDate>Fri, 27 Aug 2004 10:28:09 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53912">]]></description>
	
</item>

<item>
	<title>Figure 2-17E Pretend Flow Loop 9998 </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53911</link>
	<pubDate>Fri, 27 Aug 2004 10:27:49 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53911">]]></description>
	
</item>

<item>
	<title>Figure 2-17D Pretend Level Loop 9999</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53910</link>
	<pubDate>Fri, 27 Aug 2004 10:27:30 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53910">]]></description>
	
</item>

<item>
	<title>Figure 2-17C, Pretend Dry Pit Exhaust Fan Flow </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53909</link>
	<pubDate>Fri, 27 Aug 2004 10:27:12 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53909">]]></description>
	
</item>

<item>
	<title>Figure 2-17A, Pretend Pump Station</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53908</link>
	<pubDate>Fri, 27 Aug 2004 10:24:39 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53908">]]></description>
	
</item>

<item>
	<title>Figure 2-15, CBWTP Discrete Input Wiring Schematic</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53907</link>
	<pubDate>Fri, 27 Aug 2004 10:24:10 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53907">]]></description>
	
</item>

<item>
	<title>Figure 2-14, CBWTP Discrete Outputs Wiring Schematic</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53906</link>
	<pubDate>Fri, 27 Aug 2004 10:23:46 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53906">]]></description>
	
</item>

<item>
	<title>Figure 2-11, CBWTP Control Panel Power </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53905</link>
	<pubDate>Fri, 27 Aug 2004 10:23:23 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53905">]]></description>
	
</item>

<item>
	<title>Figure 2-10, CBWTP Control Enclosure Layout </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53903</link>
	<pubDate>Fri, 27 Aug 2004 10:22:48 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53903">]]></description>
	
</item>

<item>
	<title>Figure 2-9, CBWTP Secondary Facility Cables, Instr. &amp; Control </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53902</link>
	<pubDate>Fri, 27 Aug 2004 10:22:26 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53902">]]></description>
	
</item>

<item>
	<title>Figure 2-8, CBWTP Power Source </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53901</link>
	<pubDate>Fri, 27 Aug 2004 10:22:00 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53901">]]></description>
	
</item>

<item>
	<title>Figure 2-7A, Electrical Standards </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53900</link>
	<pubDate>Fri, 27 Aug 2004 10:21:37 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53900">]]></description>
	
</item>

<item>
	<title>Figure 2-7, CBWTP Power Source </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53899</link>
	<pubDate>Fri, 27 Aug 2004 10:21:15 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53899">]]></description>
	
</item>

<item>
	<title>Figure 2-6, CBWTP Electrical Standards, Wire No. &amp; Device No. </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53898</link>
	<pubDate>Fri, 27 Aug 2004 10:20:53 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53898">]]></description>
	
</item>

<item>
	<title>Figure 2-5, CBWTP I/O Point List </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53897</link>
	<pubDate>Fri, 27 Aug 2004 10:20:30 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53897">]]></description>
	
</item>

<item>
	<title>Figure 2-4, PLC System, Block Diagram </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53896</link>
	<pubDate>Fri, 27 Aug 2004 10:20:07 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53896">]]></description>
	
</item>

<item>
	<title>Figure 2-3, Level Instrumentation and Pump Control </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53895</link>
	<pubDate>Fri, 27 Aug 2004 10:19:45 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53895">]]></description>
	
</item>

<item>
	<title>Figure 2-2, Process &amp; Instrumentation Diagram, Process Symbols </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53894</link>
	<pubDate>Fri, 27 Aug 2004 10:19:21 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53894">]]></description>
	
</item>

<item>
	<title>Figure 2-1, Process &amp; Instrumentation, Diagram Legend </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53893</link>
	<pubDate>Fri, 27 Aug 2004 10:18:48 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53893">]]></description>
	
</item>

<item>
	<title>Figure 1-2, CBWTP Process, Control Levels of Control </title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53892</link>
	<pubDate>Fri, 27 Aug 2004 10:18:12 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53892">]]></description>
	
</item>

<item>
	<title>Figure 1-1, CBWTP Process, Control Levels of Control</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53891</link>
	<pubDate>Fri, 27 Aug 2004 10:07:27 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[<img src="/shared/cfm/image.cfm?id=53891">]]></description>
	
</item>

<item>
	<title>Table 2-1 External Alarm Lighting Standards</title>
	<link>http://www.portlandonline.com/index.cfm?c=34656&amp;a=53842</link>
	<pubDate>Thu, 26 Aug 2004 15:16:40 PDT</pubDate>
	<category>Control Systems CAD Details</category>
	
		<description><![CDATA[ PDF Document, 64kb<br>Category: <a href="/index.cfm?c=34656">Control Systems CAD Details</a> ]]></description>
	
</item>
