24.85.075 Egress Through Existing Buildings.

(Added by Ordinance No. 178831, effective November 20, 2004.) The building structure and seismic resistance of an egress path through, under or over an existing building must meet the required seismic improvement standard specified in Section 24.85.040, Table 24.85-A, under any of the following conditions:
 
A. The egress path is from an adjacent new building or addition and the new building or addition area equals 1/3 or more of the existing building area; or,
 
B. The egress path is from an adjacent existing building that undergoes alterations or a change of occupancy requiring its egress path(s) meet the seismic improvement standards as required by this Chapter; or
 
C. The additional occupant load, as determined by the OSSC, using the egress path through the existing building is 150 people or more.

Title 24 Building Regulat
Chapter 24.10 Administration and Enforcement
Chapter 24.15 Definitions
Chapter 24.20 Special Inspections
Chapter 24.25 Movings of Buildings
Chapter 24.30 Home Occupations
Chapter 24.35 Historical Buildings
Chapter 24.40 Use of and Projections Over Public Streets and Property
Chapter 24.45 Parking and Driveway Surfaces
Chapter 24.50 Flood Hazard Areas
Chapter 24.51 Wildfire Hazard Zones
Chapter 24.55 Building Demolition
Chapter 24.60 Fences
Chapter 24.65 Sidewalk Vault Openings
Chapter 24.70 Clearing, Grading and Erosion Control
Chapter 24.75 Uniform Building Address System
Chapter 24.80 (Repealed)
Chapter 24.85 Seismic Design Requirements for Existing Buildings
Chapter 24.90 Manufactured Dwelling Installation and Accessory Structures, Manufactured Dwelling Parks, Recreation Parks, Recreational Park Trailer Installation and Accessory Structures
Chapter 24.95 (Repealed)