(Amended by Ordinance No. 168626, effective Apr. 22, 1995.) Any structure
which has any or all of the conditions or defects hereinafter described, to the
extent that life, health, property, or safety of the public or its occupants are
endangered, shall be deemed to be a dangerous structure and such condition or
defects shall be abated pursuant to Sections 24.55.250 and 24.55.300 of this
Chapter.
A. Whenever the stress in any materials, member, or portion thereof,
due to all dead and live loads, is more than 1-1/2 times the working stress or
stresses allowed in the Oregon Structural Specialty Code and Fire and Life
Safety Code for new buildings of similar structure, purpose, or location.
B. Whenever any portion thereof has been damaged by fire, earthquake,
wind, flood, or by any other cause, to such an extent that the structural
strength or stability thereof is materially less than it was before such
catastrophe and is less than the minimum requirements of the Oregon State
Structural Specialty Code and Fire and Life Safety Code for new buildings of
similar structure, purpose, or location.
C. Whenever any portion or member of appurtenance thereof is likely to
fail, or to become detached or dislodged, or to collapse and thereby injure
persons or damage property.
D. Whenever any portion of a building, or any member, appurtenance, or
ornamentation of the exterior thereof is not of sufficient strength or
stability, or is not so anchored, attached or fastened in place so as to be
capable of resisting a wind pressure of one-half of that specified in the Oregon
Structural Specialty Code and Fire and Life Safety Code for new buildings of
similar structures, purpose, or location without exceeding the working stresses
permitted in the Oregon State Structural Specialty Code and Fire and Life Safety
Code for such buildings.
E. Whenever any portion thereof has wrecked, warped, buckled, or
settled to such an extent that walls or other structural portions have
materially less resistance to winds or earthquakes than is required in the case
of similar new construction.
F. Whenever the building or structure, or any portion thereof, because
of
1. dilapidation, deterioration, or decay;
2. faulty construction;
3. the removal, movement, or instability of any portion of the
ground necessary for the purpose of supporting such building;
4. the deterioration, decay, or inadequacy of its foundation; or
5. any other cause, is likely to partially or completely
collapse.
G. Whenever, for any reason, the building or structure, or any portion
thereof, is manifestly unsafe for the purpose for which it is being used.
H. Whenever the exterior walls or other vertical structural members
list, lean, or buckle to such an extent that a plumb line passing through the
center of gravity does not fall inside the middle one-third of the base.
I. Whenever the building or structure exclusive of the foundation,
shows 33 percent or more damage or deterioration of its supporting member or
members, or 50 percent damage or deterioration of its non-supporting members,
enclosing, or outside wall coverings.
J. Whenever the building or structure has been so damaged by fire,
wind, earthquake or flood or any other cause, or has become so dilapidated or
deteriorated as to become (I) an attractive nuisance, or (ii) a harbor for
vagrants or criminals.
K. Whenever any building or structure has been constructed, exists, or is
maintained in violation of any specific requirement or prohibition applicable to
such building or structure provided by the building regulations of this City, as
specified in the Oregon State Structural Specialty Code and Fire and Life Safety
Code or any law or ordinance of this State or City relating to the condition,
location, or structure or buildings.
L. Whenever any building or structure which, whether or not erected in
accordance with all applicable laws and ordinances, has in any non-supporting
part, member, or portion, less than 50 percent, or in any supporting part,
member, or portion less than 66 percent of the
1. strength,
2. fire-resisting qualities or characteristics required by law in
the case of a newly constructed building of like area, height, and occupancy
in the same location. This subsection does not apply to strength required to
resist seismic loads. For application of seismic requirements see Chapter
24.85.
M. Whenever any building or structure, because of dilapidated
condition, deterioration, damage, inadequate exits, lack of sufficient
fire-resistive construction, faulty electric wiring, gas connections, or heating
apparatus, or other cause, is a fire hazard.
N. Whenever any building or structure is in such a condition as to
constitute a public nuisance known to the common law or in equity
jurisprudence.
O. Whenever any portion of a building or structure remains on a site for
more than 30 days after the demolition or destruction of the building or
structure.
|